TesTex
provides tank floor scanning services using the TesTex Low Frequency
Elctromagnetic Technique “Falcon Mark II” system. TesTex
can also inspect the welds using the Hawkeye System.
|
|
The
Low Frequency Electromagnetic Technique (LFET) does not use permanent
magnets as is common in Magnetic Flux Leakage (MFL) equipment. The
Falcon Mark II can scan through coatings and tightly bonded scale.
The system is lightweight, battery operated, and portable.

waveform and line-plot from Falcon Mark II
|
|
The
Falcon Mark II is used to scan the floor plates for topside and
underside corrosion. Areas identified with the scanner are then
marked and verified with ultrasonics. TesTex also offers a smaller
Falcon JR. to inspect inaccessible areas around the floor such as
support legs, sumps, buckled annular plates, etc.
|
|
The
Hawkeye is used to scan the welds. It is used to detect surface and
subsurface cracks. TesTex also offers Magnetic Particle Inspections
and Vacuum Box Testing as alternatives.
|
|

|

Click on image to enlarge
|
|
- Lightweight with no permanent magnets
- Inspects through coatings and uniform scale
- Scanner Width up to 13.5”
- Inspects through ID or OD
- Smaller scanner to inspect hard to reach areas
- Optional battery operated
- Optional encoder
|
|