| TesTex provides tank floor
scanning services using the TesTex Low Frequency
Elctromagnetic Technique “Falcon Mark
II” system. TesTex can also inspect
the welds using the Hawkeye System. |
| The Low Frequency Electromagnetic
Technique (LFET) does not use permanent
magnets as is common in Magnetic Flux Leakage
(MFL) equipment. The Falcon Mark II can
scan through coatings and tightly bonded
scale. The system is lightweight, battery
operated, and portable. |
| The Falcon Mark II is used
to scan the floor plates for topside and
underside corrosion. Areas identified with
the scanner are then marked and verified
with ultrasonics. TesTex also offers a smaller
Falcon JR. to inspect inaccessible areas
around the floor such as support legs, sumps,
buckled annular plates, etc. |
| The Hawkeye is used to scan
the welds. It is used to detect surface
and subsurface cracks. TesTex also offers
Magnetic Particle Inspections and Vacuum
Box Testing as alternatives. |
|
Click
on image to enlarge
|
|
• |
Lightweight with no
permanent magnets |
• |
Inspects through coatings
and uniform scale |
• |
Scanner Width up to
13.5” |
• |
Inspects through ID
or OD |
• |
Smaller scanner to inspect
hard to reach areas |
• |
Optional battery operated |
• |
Optional encoder |
|