| OCTAVISION |
| The Octavision is a multi-channel inspection tool for the near drum (mud/steam) region of swaged or unswaged drum to drum boiler tubes. |
![]() |
This system is useful for
the detection and quantification of pitting, cracking and general corrosion
at the tube/drum interface. The Octavision is motorized and can
test 600 tubes per shift with real-time display of flaws. |
| This dry contact technique
requires minimal cleaning and is not affected by bad roll expansion.
This modular system uses specially designed software and hardware in conjunction
with motorized probe, power supply, preamplifier and special cabling.
|
![]() |
| Each motorized Octavision
scan collects data twice for instant repeatablilty / confirmation.
8 or 16 channels are used to cover the complete circumference and provide
accurate clock-oriented flaw locations. |
| boiler, corrosion, cracking, drum, inspection, mud, near, paper, pitting, pulp, recovery, rfet, steam, thinning, tube, unswaged, TesTex, octavision, steam drum, mud drum, near drum, boiler tube, pulp paper, recovery boiler |
| boiler, corrosion, cracking, drum, inspection, mud, near, paper, pitting, pulp, recovery, rfet, steam, thinning, tube, unswaged, TesTex, octavision, steam drum, mud drum, near drum, boiler tube, pulp paper, recovery boiler |
| Get more information |
| boiler, corrosion, cracking, drum, inspection, mud, near, paper, pitting, pulp, recovery, rfet, steam, thinning, tube, unswaged, TesTex, octavision, steam drum, mud drum, near drum, boiler tube, pulp paper, recovery boiler |
| OCTAVISION ADVANTAGES |
| No Couplant Required |
| High-Resolution 3-D Graphics |
| No Magnets |
| Rust and Scale Have No Impact on Signal |
| Real-Time Data Display |
| Minimal
Tube Cleaning Required |
| 100%
Coverage up to the Drum Interface |
| Accuracy Comparable to UT |
| "Bad
Roll" Expansion at Drum Interface Does Not Create a Problem |